233 lines
6.0 KiB
C
233 lines
6.0 KiB
C
// SPDX-License-Identifier: GPL-2.0
|
|
/*
|
|
* Siemens SIMATIC IPC driver for Watchdogs
|
|
*
|
|
* Copyright (c) Siemens AG, 2020-2021
|
|
*
|
|
* Authors:
|
|
* Gerd Haeussler <gerd.haeussler.ext@siemens.com>
|
|
*/
|
|
|
|
#include <linux/device.h>
|
|
#include <linux/errno.h>
|
|
#include <linux/init.h>
|
|
#include <linux/io.h>
|
|
#include <linux/ioport.h>
|
|
#include <linux/kernel.h>
|
|
#include <linux/module.h>
|
|
#include <linux/pci.h>
|
|
#include <linux/platform_data/x86/p2sb.h>
|
|
#include <linux/platform_data/x86/simatic-ipc-base.h>
|
|
#include <linux/platform_device.h>
|
|
#include <linux/sizes.h>
|
|
#include <linux/util_macros.h>
|
|
#include <linux/watchdog.h>
|
|
|
|
#define WD_ENABLE_IOADR 0x62
|
|
#define WD_TRIGGER_IOADR 0x66
|
|
#define GPIO_COMMUNITY0_PORT_ID 0xaf
|
|
#define PAD_CFG_DW0_GPP_A_23 0x4b8
|
|
#define SAFE_EN_N_427E 0x01
|
|
#define SAFE_EN_N_227E 0x04
|
|
#define WD_ENABLED 0x01
|
|
#define WD_TRIGGERED 0x80
|
|
#define WD_MACROMODE 0x02
|
|
|
|
#define TIMEOUT_MIN 2
|
|
#define TIMEOUT_DEF 64
|
|
#define TIMEOUT_MAX 64
|
|
|
|
#define GP_STATUS_REG_227E 0x404D /* IO PORT for SAFE_EN_N on 227E */
|
|
|
|
static bool nowayout = WATCHDOG_NOWAYOUT;
|
|
module_param(nowayout, bool, 0000);
|
|
MODULE_PARM_DESC(nowayout, "Watchdog cannot be stopped once started (default="
|
|
__MODULE_STRING(WATCHDOG_NOWAYOUT) ")");
|
|
|
|
static struct resource gp_status_reg_227e_res =
|
|
DEFINE_RES_IO_NAMED(GP_STATUS_REG_227E, SZ_1, KBUILD_MODNAME);
|
|
|
|
static struct resource io_resource_enable =
|
|
DEFINE_RES_IO_NAMED(WD_ENABLE_IOADR, SZ_1,
|
|
KBUILD_MODNAME " WD_ENABLE_IOADR");
|
|
|
|
static struct resource io_resource_trigger =
|
|
DEFINE_RES_IO_NAMED(WD_TRIGGER_IOADR, SZ_1,
|
|
KBUILD_MODNAME " WD_TRIGGER_IOADR");
|
|
|
|
/* the actual start will be discovered with p2sb, 0 is a placeholder */
|
|
static struct resource mem_resource =
|
|
DEFINE_RES_MEM_NAMED(0, 0, "WD_RESET_BASE_ADR");
|
|
|
|
static u32 wd_timeout_table[] = {2, 4, 6, 8, 16, 32, 48, 64 };
|
|
static void __iomem *wd_reset_base_addr;
|
|
|
|
static int wd_start(struct watchdog_device *wdd)
|
|
{
|
|
outb(inb(WD_ENABLE_IOADR) | WD_ENABLED, WD_ENABLE_IOADR);
|
|
return 0;
|
|
}
|
|
|
|
static int wd_stop(struct watchdog_device *wdd)
|
|
{
|
|
outb(inb(WD_ENABLE_IOADR) & ~WD_ENABLED, WD_ENABLE_IOADR);
|
|
return 0;
|
|
}
|
|
|
|
static int wd_ping(struct watchdog_device *wdd)
|
|
{
|
|
inb(WD_TRIGGER_IOADR);
|
|
return 0;
|
|
}
|
|
|
|
static int wd_set_timeout(struct watchdog_device *wdd, unsigned int t)
|
|
{
|
|
int timeout_idx = find_closest(t, wd_timeout_table,
|
|
ARRAY_SIZE(wd_timeout_table));
|
|
|
|
outb((inb(WD_ENABLE_IOADR) & 0xc7) | timeout_idx << 3, WD_ENABLE_IOADR);
|
|
wdd->timeout = wd_timeout_table[timeout_idx];
|
|
return 0;
|
|
}
|
|
|
|
static const struct watchdog_info wdt_ident = {
|
|
.options = WDIOF_MAGICCLOSE | WDIOF_KEEPALIVEPING |
|
|
WDIOF_SETTIMEOUT,
|
|
.identity = KBUILD_MODNAME,
|
|
};
|
|
|
|
static const struct watchdog_ops wdt_ops = {
|
|
.owner = THIS_MODULE,
|
|
.start = wd_start,
|
|
.stop = wd_stop,
|
|
.ping = wd_ping,
|
|
.set_timeout = wd_set_timeout,
|
|
};
|
|
|
|
static void wd_secondary_enable(u32 wdtmode)
|
|
{
|
|
u16 resetbit;
|
|
|
|
/* set safe_en_n so we are not just WDIOF_ALARMONLY */
|
|
if (wdtmode == SIMATIC_IPC_DEVICE_227E) {
|
|
/* enable SAFE_EN_N on GP_STATUS_REG_227E */
|
|
resetbit = inb(GP_STATUS_REG_227E);
|
|
outb(resetbit & ~SAFE_EN_N_227E, GP_STATUS_REG_227E);
|
|
} else {
|
|
/* enable SAFE_EN_N on PCH D1600 */
|
|
resetbit = ioread16(wd_reset_base_addr);
|
|
iowrite16(resetbit & ~SAFE_EN_N_427E, wd_reset_base_addr);
|
|
}
|
|
}
|
|
|
|
static int wd_setup(u32 wdtmode)
|
|
{
|
|
unsigned int bootstatus = 0;
|
|
int timeout_idx;
|
|
|
|
timeout_idx = find_closest(TIMEOUT_DEF, wd_timeout_table,
|
|
ARRAY_SIZE(wd_timeout_table));
|
|
|
|
if (inb(WD_ENABLE_IOADR) & WD_TRIGGERED)
|
|
bootstatus |= WDIOF_CARDRESET;
|
|
|
|
/* reset alarm bit, set macro mode, and set timeout */
|
|
outb(WD_TRIGGERED | WD_MACROMODE | timeout_idx << 3, WD_ENABLE_IOADR);
|
|
|
|
wd_secondary_enable(wdtmode);
|
|
|
|
return bootstatus;
|
|
}
|
|
|
|
static struct watchdog_device wdd_data = {
|
|
.info = &wdt_ident,
|
|
.ops = &wdt_ops,
|
|
.min_timeout = TIMEOUT_MIN,
|
|
.max_timeout = TIMEOUT_MAX
|
|
};
|
|
|
|
static int simatic_ipc_wdt_probe(struct platform_device *pdev)
|
|
{
|
|
struct simatic_ipc_platform *plat = pdev->dev.platform_data;
|
|
struct device *dev = &pdev->dev;
|
|
struct resource *res;
|
|
int ret;
|
|
|
|
switch (plat->devmode) {
|
|
case SIMATIC_IPC_DEVICE_227E:
|
|
res = &gp_status_reg_227e_res;
|
|
if (!request_muxed_region(res->start, resource_size(res), res->name)) {
|
|
dev_err(dev,
|
|
"Unable to register IO resource at %pR\n",
|
|
&gp_status_reg_227e_res);
|
|
return -EBUSY;
|
|
}
|
|
fallthrough;
|
|
case SIMATIC_IPC_DEVICE_427E:
|
|
wdd_data.parent = dev;
|
|
break;
|
|
default:
|
|
return -EINVAL;
|
|
}
|
|
|
|
if (!devm_request_region(dev, io_resource_enable.start,
|
|
resource_size(&io_resource_enable),
|
|
io_resource_enable.name)) {
|
|
dev_err(dev,
|
|
"Unable to register IO resource at %#x\n",
|
|
WD_ENABLE_IOADR);
|
|
return -EBUSY;
|
|
}
|
|
|
|
if (!devm_request_region(dev, io_resource_trigger.start,
|
|
resource_size(&io_resource_trigger),
|
|
io_resource_trigger.name)) {
|
|
dev_err(dev,
|
|
"Unable to register IO resource at %#x\n",
|
|
WD_TRIGGER_IOADR);
|
|
return -EBUSY;
|
|
}
|
|
|
|
if (plat->devmode == SIMATIC_IPC_DEVICE_427E) {
|
|
res = &mem_resource;
|
|
|
|
ret = p2sb_bar(NULL, 0, res);
|
|
if (ret)
|
|
return ret;
|
|
|
|
/* do the final address calculation */
|
|
res->start = res->start + (GPIO_COMMUNITY0_PORT_ID << 16) +
|
|
PAD_CFG_DW0_GPP_A_23;
|
|
res->end = res->start + SZ_4 - 1;
|
|
|
|
wd_reset_base_addr = devm_ioremap_resource(dev, res);
|
|
if (IS_ERR(wd_reset_base_addr))
|
|
return PTR_ERR(wd_reset_base_addr);
|
|
}
|
|
|
|
wdd_data.bootstatus = wd_setup(plat->devmode);
|
|
if (wdd_data.bootstatus)
|
|
dev_warn(dev, "last reboot caused by watchdog reset\n");
|
|
|
|
if (plat->devmode == SIMATIC_IPC_DEVICE_227E)
|
|
release_region(gp_status_reg_227e_res.start,
|
|
resource_size(&gp_status_reg_227e_res));
|
|
|
|
watchdog_set_nowayout(&wdd_data, nowayout);
|
|
watchdog_stop_on_reboot(&wdd_data);
|
|
return devm_watchdog_register_device(dev, &wdd_data);
|
|
}
|
|
|
|
static struct platform_driver simatic_ipc_wdt_driver = {
|
|
.probe = simatic_ipc_wdt_probe,
|
|
.driver = {
|
|
.name = KBUILD_MODNAME,
|
|
},
|
|
};
|
|
|
|
module_platform_driver(simatic_ipc_wdt_driver);
|
|
|
|
MODULE_LICENSE("GPL v2");
|
|
MODULE_ALIAS("platform:" KBUILD_MODNAME);
|
|
MODULE_AUTHOR("Gerd Haeussler <gerd.haeussler.ext@siemens.com>");
|