hwmon: (mlxreg-fan) Extend number of supported fans
Some new big modular systems can be equipped with up to 24 fans. Extend maximum number of fans accordingly. Signed-off-by: Vadim Pasternak <vadimp@nvidia.com> Link: https://lore.kernel.org/r/20230824164006.26868-1-vadimp@nvidia.com Signed-off-by: Guenter Roeck <linux@roeck-us.net>
This commit is contained in:
parent
a1f38987dd
commit
dadca53dd9
|
@ -12,7 +12,7 @@
|
|||
#include <linux/regmap.h>
|
||||
#include <linux/thermal.h>
|
||||
|
||||
#define MLXREG_FAN_MAX_TACHO 14
|
||||
#define MLXREG_FAN_MAX_TACHO 24
|
||||
#define MLXREG_FAN_MAX_PWM 4
|
||||
#define MLXREG_FAN_PWM_NOT_CONNECTED 0xff
|
||||
#define MLXREG_FAN_MAX_STATE 10
|
||||
|
@ -300,6 +300,16 @@ static const struct hwmon_channel_info * const mlxreg_fan_hwmon_info[] = {
|
|||
HWMON_F_INPUT | HWMON_F_FAULT,
|
||||
HWMON_F_INPUT | HWMON_F_FAULT,
|
||||
HWMON_F_INPUT | HWMON_F_FAULT,
|
||||
HWMON_F_INPUT | HWMON_F_FAULT,
|
||||
HWMON_F_INPUT | HWMON_F_FAULT,
|
||||
HWMON_F_INPUT | HWMON_F_FAULT,
|
||||
HWMON_F_INPUT | HWMON_F_FAULT,
|
||||
HWMON_F_INPUT | HWMON_F_FAULT,
|
||||
HWMON_F_INPUT | HWMON_F_FAULT,
|
||||
HWMON_F_INPUT | HWMON_F_FAULT,
|
||||
HWMON_F_INPUT | HWMON_F_FAULT,
|
||||
HWMON_F_INPUT | HWMON_F_FAULT,
|
||||
HWMON_F_INPUT | HWMON_F_FAULT,
|
||||
HWMON_F_INPUT | HWMON_F_FAULT),
|
||||
HWMON_CHANNEL_INFO(pwm,
|
||||
HWMON_PWM_INPUT,
|
||||
|
|
Loading…
Reference in New Issue